eLABa objektas:   "Polianilino darinių tyrimas ir panaudojimas askorbo rūgšties jutikliuose", 2009,D:20090629:130203-74269
E. dokumentai
ETD (LT)
visi dokumentai ...
URL nuoroda http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2009~D_20090629_130203-74269
Dokumentas Magistro darbas
Prieigos teisės Laisvai prieinamas internete.
Institucija Vilniaus pedagoginis universitetas
Mokslo kryptis 03 P - Chemija
Atsakomybė Griškalauskaitė, Jolanta - Magistro baigiamojo darbo autorius
Malinauskas, Albertas - Magistro baigiamojo darbo vadovas
Jurevičiūtė, Irena - Magistro baigiamojo darbo vadovas
Ščit, Olga - Magistro baigiamojo darbo recenzentas
Gefenas, Vladas - Magistro baigiamojo darbo vertinimo komisijos narys
Giraitis, Raimondas - Magistro baigiamojo darbo vertinimo komisijos narys
Vitėnienė, Irena - Magistro baigiamojo darbo vertinimo komisijos narys
Šalkus, Bronislovas - Magistro baigiamojo darbo vertinimo komisijos narys
Tumkevičius, Sigitas - Magistro baigiamojo darbo vertinimo komisijos pirmininkas
Vilniaus pedagoginis universitetas - Mokslinį laipsnį teikianti institucija
Antraštė (-ės) Polianilino darinių tyrimas ir panaudojimas askorbo rūgšties jutikliuose
The investigation of PANI derivatives and their application as ascorbate sensors
Santrauka [EN]

The Epsilon potentiometer model combined with a PC running Epsilon EC-2000-XP (Ver. 1.40.67_NT) software was used in these theses. During the research, a three-electrode cell was used. A platinum electrode was utilised as the working and auxiliary electrode. An Ag/AgCl/KClsot electrode was used as reference electrode. All values of the potentials refer to this electrode.

An POT layer was deposited under potentiostatic or potentiodynamic conditions on platinum electrode by varying parameters of the experiment. Potentiodynamic polymer formation measurements were performed by alternating the electrode potential from 0.1V to 1.0V and from 0.1V to 1.2V. When modifying Pt electrode, 10 or 20 potential cycles were performed. The potential scan rate was 10, 20, 50, and 100 mV/s. Potentiostatic polymer formation measurements were performed under the constant potential Econst 0.9V, 1.0V, and 1.2V, and the time of coating (tcoating) was 1, 3 or 5 minutes. Poly (o-methylaniline) modified electrodes can be used for the analysis of ascorbic acid in solutions with pH values 5,5. Within the concentration interval of ascorbic acid between 0,1mM and 1mM, a linear dependence between oxidation limit currents and concentration was observed when ascorbic acid measurements were carried out potentiostatic conditions. The lowest sensing limit of ascorbic acid was 0,1mM.

Raktažodžiai: Ascorbic acid, poly(o-toluidine), electrooxidation